Skip to content
SPM Instrument

SLD2xx Series Ex Vibration Transducers (ATEX)

Intrinsically safe accelerometers for permanent installation in explosive atmospheres

Part number
SLD244 / SLD244S
SLD2xx Series Ex Vibration Transducers (ATEX)

The Ex version of the SLD1xx series: the same measuring performance with explosive-atmosphere approval. It connects directly to IS instruments with matching IS parameters; connection to non-certified equipment is made through a suitable Ex barrier (e.g. SPM 17310).

Highlights

  • CE, ATEX and IECEx certified intrinsically safe (Ex ia) transducers
  • 100 mV/g sensitivity, 2 Hz – 10 kHz linear frequency range
  • Optional temperature measurement on SLD244 (−20 to +120 °C, ±4 °C)
  • Top entry (SLD244) and side entry (SLD244S) versions
  • Stainless acid-proof steel casing, IP66/67

The housing and base are stainless acid-proof steel, suitable for aggressive environments. The transducer is installed on a flat machine surface and connected with a twisted pair cable using a 2-pin MIL-C-5015 connector. Mechanical fastening uses mounting studs with M6, M8, M10 or UNF 1/4" thread.

SLD244 has top entry and offers an optional temperature measurement: used with Intellinova Parallel EN it measures −20 to +120 °C with ±4 °C accuracy. Measurement is performed above 10 kHz, where it does not interfere with the acceleration signal.

SLD244S has side entry and a captured bolt for installation.

The two models differ in Ex marking and temperature limits; choose according to the installation zone.

Variants

VariantSLD244Top entrySLD244SSide entry
Cable entryTopSide (captured bolt)
Ex markingEx ia I Ma · Ex ia IIC T4 Ga · I M1 Ex ia IIC T3 Ga · II 1G Ex ia IIIC T135 °C Da · II 1D Ex ia IIIC T145 °C DaI M1 Ex ia I Ma · II 1G Ex ia IIC T4 Ga · II 1D Ex ia IIIC T114 °C Da, Ta −40 to +100 °C
IS parametersUi 28 V · Ii 93 mA · Pi 0.66 W · Ci 58 nF · Li 10 µHUi 28 V · Ii 93 mA · Pi 0.66 W · Ci 54 nF · Li 5 µH
Operating temperatureT3: −40 to +125 °C · T4: −40 to +115 °C−40 … +90 °C
Temperature measurementOptional — −20 to +120 °C (±4 °C)No
Bias point11 to 13 V (typical 12 V)10 to 13 V (typical 12 V)
Power requirements12 – 24 V, 2 – 5 mA24 V, 2 – 5 mA
Mounting threadM8 tapped hole (M6 / M10 / UNF 1/4" via stud)M8 x 1.25
Weight115 g200 g

Part numbers

Part numberDescription
SLD244 TBTop entry Ex transducer, 2-pin MIL-C-5015 connector
SLD244S-M8Side entry Ex transducer, M8 x 1.25

Accessories

Part numberDescription
17310Ex barrier — for connection to non-certified measuring equipment
151682-pin MIL-C-5015 connector, composite
161002-pin MIL-C-5015 connector, stainless steel
18177 / 18178 / 18179 / 18180Mounting stud M8 to M6 / M10 / UNF 1/4"x28 / M8