SLD2xx Series Ex Vibration Transducers (ATEX)
Intrinsically safe accelerometers for permanent installation in explosive atmospheres
- Part number
- SLD244 / SLD244S
- Brand
- SPM Instrument

The Ex version of the SLD1xx series: the same measuring performance with explosive-atmosphere approval. It connects directly to IS instruments with matching IS parameters; connection to non-certified equipment is made through a suitable Ex barrier (e.g. SPM 17310).
Highlights
- CE, ATEX and IECEx certified intrinsically safe (Ex ia) transducers
- 100 mV/g sensitivity, 2 Hz – 10 kHz linear frequency range
- Optional temperature measurement on SLD244 (−20 to +120 °C, ±4 °C)
- Top entry (SLD244) and side entry (SLD244S) versions
- Stainless acid-proof steel casing, IP66/67
The housing and base are stainless acid-proof steel, suitable for aggressive environments. The transducer is installed on a flat machine surface and connected with a twisted pair cable using a 2-pin MIL-C-5015 connector. Mechanical fastening uses mounting studs with M6, M8, M10 or UNF 1/4" thread.
SLD244 has top entry and offers an optional temperature measurement: used with Intellinova Parallel EN it measures −20 to +120 °C with ±4 °C accuracy. Measurement is performed above 10 kHz, where it does not interfere with the acceleration signal.
SLD244S has side entry and a captured bolt for installation.
The two models differ in Ex marking and temperature limits; choose according to the installation zone.
Variants
| Variant | SLD244Top entry | SLD244SSide entry |
|---|---|---|
| Cable entry | Top | Side (captured bolt) |
| Ex marking | Ex ia I Ma · Ex ia IIC T4 Ga · I M1 Ex ia IIC T3 Ga · II 1G Ex ia IIIC T135 °C Da · II 1D Ex ia IIIC T145 °C Da | I M1 Ex ia I Ma · II 1G Ex ia IIC T4 Ga · II 1D Ex ia IIIC T114 °C Da, Ta −40 to +100 °C |
| IS parameters | Ui 28 V · Ii 93 mA · Pi 0.66 W · Ci 58 nF · Li 10 µH | Ui 28 V · Ii 93 mA · Pi 0.66 W · Ci 54 nF · Li 5 µH |
| Operating temperature | T3: −40 to +125 °C · T4: −40 to +115 °C | −40 … +90 °C |
| Temperature measurement | Optional — −20 to +120 °C (±4 °C) | No |
| Bias point | 11 to 13 V (typical 12 V) | 10 to 13 V (typical 12 V) |
| Power requirements | 12 – 24 V, 2 – 5 mA | 24 V, 2 – 5 mA |
| Mounting thread | M8 tapped hole (M6 / M10 / UNF 1/4" via stud) | M8 x 1.25 |
| Weight | 115 g | 200 g |
Part numbers
| Part number | Description |
|---|---|
| SLD244 TB | Top entry Ex transducer, 2-pin MIL-C-5015 connector |
| SLD244S-M8 | Side entry Ex transducer, M8 x 1.25 |
Accessories
| Part number | Description |
|---|---|
| 17310 | Ex barrier — for connection to non-certified measuring equipment |
| 15168 | 2-pin MIL-C-5015 connector, composite |
| 16100 | 2-pin MIL-C-5015 connector, stainless steel |
| 18177 / 18178 / 18179 / 18180 | Mounting stud M8 to M6 / M10 / UNF 1/4"x28 / M8 |